1 30" AND 36" WALL-MOUNT RANGE HOOD Universal Installation Instructions, Use, & Care Guide For questions about features, operation/per
10 STEP 1: MOUNTING THE RANGE HOOD 1. After preparing the location, use two or more people, hang the range hood on the two mounting screws (Part A)
11 STEP 2: CONNECTING VENT SYSTEM COMPLETE INSTALLATION FOR VENTED MODE 1. Install the non-return air flap on top of hood (if removed for shipping)
12 COMPLETE INSTALLATION FOR VENTLESS (RECIRCULATING) MODE IMPORTANT: Do not install the exhaust pipe and disconnect the power 1. Remove the filt
13 STEP 3: INSTALL VENT COVERS 1. When using both inner and outer vent covers, push lower cover down onto hood and lift upper cover to ceiling and
14 RANGE HOOD USE The range hood is designed to remove smoke, vapors, and odors. For best results, start the hood before cooking. After, the cooking
15 RANGE HOOD CONTROLS Operating the lights The On/Off light button controls both lights. Press once for “ON” and again for “OFF”. Operating the
16 RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and panel filters frequently according to the following instructions. Replace the panel filte
17 Non-Vented (recirculating) Installation Filters: The carbon filter is not washable. It should last up to 6 months with normal use. For replacement
18 TROUBLE SHOOTING Potential Effect of Failure Potential Cause(s) Recommended Action(s) Lamp does not turn ON Electronic Control does not work.
19 - Hold and press main connectors attached in the white plastic. - Push inwards the motor/lamp connectors until the locking system on connectors is
2 TABLE OF CONTENTS RANGE HOOD SAFETY ...2 INSTALLATIO
20 SHOPRANGEHOODS.COM MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For three year from the date of purchase, when this major appliance is operated and
3 IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, READ THE FOLLOWING: Use this unit only
4 INSTALLATION REQUIREMENTTOOLS AND PARTS REQUIREMENTS Electrical drill or ratchet driver 1/2” drill bit for drilling pilot holes 1 ¼” drill bit for
5 INSTALLATION DIMENSIONS A. Countertop height B. Hood height from ceiling to bottom of the range hood filter surface: D-A-C=B C. 29” (73.66 cm
6 VENTILATION REQUIREMENTS Range hoods must be ventilated to the outdoors, except for non-vented (recirculating) installations. Do not ventilat
7 Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for all vent pieces used in the sy
8 INSTALLATION INSTRUCTIONS PREPARING THE LOCATION It is recommended for the vent system to be installed before hood is installed. Before makin
9 Vent Cover Bracket Installation 5. Mark the hole’s location. 6. Attach chimney mounting bracket to the wall by using two M5 x 8 screws. A. Centr